Arslan Metal offers Sheet Lead for many applications that include Radiation Shielding - laboratories, hospitals, dental offices and veterinary clinics, Construction – flat and pitched roofing, mosques roofing, clading, flashing and waterproofing, gutters, parapets, Corrosion Protection - acid Storage and handling - autoclaves movable lead screens sound barriers and sound proofing, tank lining vibration absorbers and all lead detail work. They are produced that Lead fluid is casting to the moulds and follows to the rolling machines,to be lead sheets.
Dimensions Table For Lead Sheet
Thickness |
12" x 24" (1Ft x 2Ft) 300 x 600mm |
12" x 36" (1Ft x 3Ft) 300 x 900mm |
12" x 48" (1Ft x 4Ft) 300 x 1200mm |
12" x 60" (1Ft x 5Ft) 300 x 1500 |
12" x 72" (1Ft x 6Ft) 300 x 1800mm |
12" x 84" (1Ft x 7Ft) 300x 2000mm |
12" x 96" (1 Ft x 8Ft) 300 x 2400mm |
|||||||||
inch | mm | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | |
1/32 | 0.8 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | |
5/128 | 1.0 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | |
3/64 | 1.2 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | |
1/16 | 1.6 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | |
5/64 | 2.0 | 4,64 | 22,68 | 4,64 | 22,68 | 4,64 | 22,68 | 4,64 | 22,68 | 4,64 | 22,68 | 4,64 | 22,68 | 4,64 | 22,68 | |
3/32 | 2.4 | 5,57 | 27,22 | 5,57 | 27,22 | 5,57 | 27,22 | 5,57 | 27,22 | 5,57 | 27,22 | 5,57 | 27,22 | |||
1/8 | 3.2 | 7,43 | 36,29 | 7,43 | 36,29 | 7,43 | 36,29 | 7,43 | 36,29 | |||||||
5/32 | 4.0 | 9,29 | 45,36 | 9,29 | 45,36 | 9,29 | 45,36 | |||||||||
3/16 | 4.8 | 11,15 | 54,43 | 11,15 | 54,43 | |||||||||||
7/32 | 5.6 | 13,01 | 63,50 | 13,01 | 63,50 | |||||||||||
1/4 | 6.4 | 14,86 | 72,58 |
Thickness | 24" x 24" (2Ft x 2Ft) 600x 600mm | 24" x 36" (2Ft x 3Ft) 600 x 900mm | 24" x 48" (2Ft x 4Ft) 600 x 1200mm | 24" x 60" (2Ft x 5Ft) 600 x 1500mm | 24" x 72" (2Ft x 6Ft) 600 x 1800mm | 24" x 84" (2Ft x 7Ft) 600x 2000mm | 24" x 96" (2 Ft x 8Ft) 600 x 2400mm | ||||||||
inch | mm | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 |
1/32 | 0.8 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 |
5/128 | 1.0 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 |
3/64 | 1.2 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | ||
1/16 | 1.6 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | 3,72 | 18,14 | ||||||
5/64 | 2.0 | 4,64 | 22,68 | 4,64 | 22,68 | 4,64 | 22,68 | ||||||||
3/32 | 2.4 | 5,57 | 27,22 | 5,57 | 27,22 | ||||||||||
1/8 | 3.2 | 7,43 | 36,29 | ||||||||||||
5/32 | 4.0 | 9,29 | 45,36 |
Thickness |
36" x 36" (3Ft x 3Ft) 900x 900mm |
36" x 48" (3Ft x 4Ft) 900 x 1200mm |
36" x 60" (3Ft x 5Ft) 900 x 1500mm |
36" x 72" (3Ft x 6Ft) 900 x 1800mm |
36" x 84" (3Ft x 7Ft) 900 x 2000mm |
36" x 96" (3Ft x 8Ft) 900x 2400mm |
|||||||
inch | mm | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 | Lbs/Ft2 | Kg/m2 |
1/32 | 0.8 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9,07 | 1,86 | 9.07 |
5/128 | 1.0 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | 2,32 | 11,34 | ||||
3/64 | 1.2 | 2,79 | 13,61 | 2,79 | 13,61 | 2,79 | 13,61 | ||||||
1/16 | 1.6 | 3,72 | 18,14 |
Above weights are based on Pure Lead (99.97% Min.) Other sizes available upon request
X-RAY
It is a well-known fact that X-Rays, unless properly controlled and directed, are very harmful to the human body and have even been known to cause death. As a consequence, various materials are being utilizes for the insulating of the X-Ray tubes. There are two general methods of securing this protection. One is by the use of protective plasters, such as barium sulphate plaster, and the other is the use of sheet lead. In the use of plaster there are couple of disadvantages. But sheet lead has none of these disadvantages and is consequently considered the best possible protection. The Advisory Committee on X-Ray Protection of the International Congress of Radiology specifically warns against the use of protective plasters in installations of over 75 kV.The thickness of lead required varies with the power of the X-Ray apparatus.
The thickness recommended by the Second International Congress of Radiology are presented in the accompanying table:
Recommended Thickness of Lead Shielding for X-Ray Rooms
X-Rays generated by peak voltages not exceeding | Minimum thickness of Lead | Weight (Kg/ m2) | |
(mm) | (Inch) | ||
75 kV | 1.0 | 0.039 | 9.86 |
100 kV | 1.5 | 0.059 | 19.7 |
125 kV | 2.0 | 0.079 | 24.6 |
150 kV | 2.5 | 0.098 | 34.5 |
175 kV | 3.0 | 0.118 | 39.4 |
200 kV | 4.0 | 0.157 | 49.3 |
225 kV | 5.0 | 0.197 | 64.1 |
300 kV | 9.0 | 0.354 | 118.4 |
400 kV | 15.0 | 0.591 | 187.5 |
500 kV | 22.0 | 0.369 | 276.3 |
600 kV | 34.0 | 1.343 | 399.7 |
900 kV | 51.0 | 2.000 | 592.1 |
Required Lead Shielding Thickness for Gamma Rays
The table below, prepared by the American National Bureau of Standards, is frequently used in determining the thickness of lead needed for shielding from gamma ray sources in laboratories.
Energy (Mev- 1 million electron-volts.) | |||||||||
Activity | 0.2 | 0.5 | 0.8 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 4.0 |
10 mc | -0.14 | -0.36 | -0.27 | -0.11 | +0.37 | +0.78 | +1.15 | +1.40 | +1.70 |
20 mc | -0.09 | +0.00 | +0.41 | +0.76 | +1.57 | +2.16 | +2.63 | +2.91 | +3.21 |
50 mc | -0.01 | +0.47 | +1.31 | +1.90 | +3.15 | +4.00 | +4.57 | +4.90 | +5.20 |
100 mc | +0.06 | +0.82 | +1.99 | +2.77 | +4.34 | +5.38 | +6.05 | +6.41 | +6.71 |
200 mc | +0.10 | +1.17 | +2.67 | +3.63 | +5.54 | +6.77 | +7.52 | +7.92 | +8.21 |
500 mc | +0.17 | +1.64 | +3.57 | +4.78 | +7.12 | +8.60 | +9.47 | +9.91 | +10.21 |
1 c | +0.23 | +1.99 | +4.25 | +5.65 | +8.31 | +9.99 | +10.95 | +11.41 | +11.71 |
2 c | +0.28 | +2.35 | +4.93 | +6.52 | +9.51 | +11.37 | +12.42 | +12.92 | +13.22 |
5 c | +0.36 | +2.81 | +5.82 | +7.66 | +11.09 | +13.21 | +14.37 | +14.91 | +15.21 |
10 c | +0.41 | +3.17 | +6.50 | +8.52 | +12.28 | +14.59 | +15.85 | +16.42 | +16.72 |
20 c | +0.47 | +3.52 | +7.18 | +9.39 | +13.48 | +15.98 | +17.32 | +17.93 | +18.23 |
50 c | +0.54 | +3.99 | +8.08 | +10.54 | +15.06 | +17.81 | +19.27 | +19.92 | +20.22 |
100 c | +0.60 | +4.34 | +8.76 | +11.40 | +16.25 | +19.20 | +20.75 | +21.43 | +21.72 |
Danger Range | Artı | Artı | Artı | Artı | Artı | Artı | Artı | Artı | Artı |
20 cm | +0.26 | +1.64 | +3.16 | +4.02 | +5.55 | +6.44 | +6.85 | +7.00 | +7.00 |
50 cm | +0.11 | +0.71 | +1.36 | +1.73 | +2.39 | +2.77 | +2.95 | +3.01 | +3.01 |
1 M | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 |
2 M | -0.11 | -0.71 | -1.36 | -1.73 | -2.39 | -2.77 | -2.95 | -3.01 | -3.01 |
5 M | -0.26 | -1.64 | -3.16 | -4.02 | -5.55 | -6.44 | -6.85 | -7.00 | -7.00 |
10 M | -0.37 | -2.35 | -4.52 | -5.76 | -7.94 | -9.21 | -9.80 | -10.01 | -10.01 |
Working time hr/day | Artı | Artı | Artı | Artı | Artı | Artı | Artı | Artı | Artı |
1 | -0.17 | -1.06 | -2.04 | -2.60 | -3.59 | -4.16 | -4.42 | -4.52 | -4.52 |
2 | -0.11 | -0.71 | -1.36 | -1.73 | -2.39 | -2.77 | -2.95 | -3.01 | -3.01 |
4 | -0.06 | -0.35 | -0.68 | -0.87 | -1.20 | -1.39 | -1.47 | -1.51 | -1.51 |
8 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 | +0.00 |
24 | +0.09 | +0.56 | +1.08 | +1.37 | +1.89 | +2.20 | +2.34 | +2.39 | +2.3 |
SOUND PROOFING
Soundproofing is becoming ever more important because of the noise polluting our environment. Sheet lead is one of the basic materials for acoustic control systems, lead is an extremely efficient barrier material by itself or fastened to studs as part of a wall. Arslan Metal’s lead sheet products are widely used in different applications for sound proofing.
Below the table, lead for noise control compared to other materials
Material | Thickness required in inches (mm) | ||
Moderately Noisy Office | Quiet Office | Very Quite Office | |
Plywood | 0,932 | 1,694 | 3,335 |
Sand Plaster | 0,050 | 1,130 | 2,260 |
Pine | 0,033 | 2,387 | |
Intensive Concrete | 0,035 | 1,231 | 3,098 |
Aluminum | 0,033 | 1,447 | 2,870 |
Steel | 0,001 | 0,050 | 1,778 |
Lead | 0,007 | 0,034 | 0,137 |